Function
Code
Parameter Name Setting Range Min. Unit Default Property
2: AI2
3: AI3
5: Via communication
Range of analog input corresponds
to F2-10
FL-22
Torque upper limit of
motor 3
0.0%–200.0% 0.1% 150.0% ƿ
FL-23
PPR of the encoder
for motor 3
1–65535 1 1024 ƾ
FL-24 Motor 3 control mode
0: Sensorless flux vector control
(SFVC)
1: Closed-loop vector control (CLVC)
2: Voltage/Frequency (V/F)
1 0 ƾ
FL-25
Motor 3 acceleration
time 0
0.1–1000.0s 0.1s 3.0s ƾ
FL-26
Motor 3 deceleration
time 0
0.1–1000.0s 0.1s 3.0s ƾ
FL-27
Motor 2 acceleration
time 1
0.1–1000.0s 0.1s 10.0s ƾ
FL-28
Motor 2 deceleration
time 1
0.1–1000.0s 0.1s 10.0s ƾ
FL-29 Motor 3 torque boost
0.0: Automatic torque boost
0.1%–30.0%
0.1% 1.0% ƿ
FL-30
Motor 3 oscillation
suppression gain
0–100 1
Model
dependent
ƿ