EasyManua.ls Logo

Inovance IS 300 Series - Page 75

Inovance IS 300 Series
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix IS300 Series Servo Drive User Manual
- 74 -
Function
Code
Name Setting Range Min. Unit Default Property
A3-22
Setting of max.
output speed in
pressure control
0.0%–100.0% 0.1% 10.0%
A3-23
Setting of min.
output speed in
pressure control
0.0%–100.0% 0.1% 60.0%
A3-24
Output delay time
in pressure control
0.000–10.000s 0.001s 0.100s
A3-25
Reference oil
pressure S lter
time
0.000–10.000s 0.001s 0.030s
A3-26 to
A3-31
Reserved - - -
A3-32 Min. slave input 0.0%–A3-34 0.1% 0.0%
A3-33
Min. slave input
frequency
-100.0%–100.0% 0.1% 0.0%
A3-34
Medium slave
input
A3-32–A3-36 0.1% 0.0%
A3-35
Medium slave
input frequency
-100.0%–100.0% 0.1% 0.0%
A3-36 Max. slave input A3-34–100.0% 0.1% 100.0%
A3-37
Max. slave input
frequency
-100.0%–100.0% 0.1% 100.0%
Group A4
A4-00
Rotational sped
lter time
0–5.000s 0.001s 0.005s
A4-01 Current lter time 0–5.000s 0.001s 0.010s
A4-02 Reserved - - - -
A4-03
Overshoot
restraining factor 1
20–500 1 100
A4-04
Overshoot
restraining factor 2
20–500 1 100
Group F0: Basic Functions
F0-00 Model display
1: G type (heavy load)
2: Reserved
1
Model
dependent
F0-01 Control mode
0: Reserved
1: Speed sensor vector
conrol (VC)
2: V/F control
1 1

Related product manuals