IS300 Series Servo Drive User Manual Appendix
- 75 -
Function
Code
Name Setting Range Min. Unit Default Property
F0-02
Command source
selection
0: Operation panel (LED
indicator off)
1: Terminal input (LED
indicator on)
2: Via serial port (LED
indicator blinking)
1 0
F0-03
Main frequency
source X selection
0: Digital setting (preset
frequency F0-08, you can
make modication via UP/
DOWN, non-retentive at
power failure)
1: Digital setting (preset
frequency F0-08, you can
make modication via UP/
DOWN, retentive at power
failure)
2: AI1
3: AI2
4: AI3
5: Reserved
6: Multi-speed
7: Reserved
8: Reserved
9: Via communication
1 1
F0-04
Auxiliary frequency
source Y selection
0: Digital setting (preset
frequency F0-08, you can
make modication via UP/
DOWN, non-retentive at
power failure)
1: Digital setting (preset
frequency F0-08, you can
make modication via UP/
DOWN, retentive at power
failure)
2: AI1
3: AI2
4: AI3
5: Reserved
6: Multi-speed
7: Reserved
8: Reserved
9: Via communication
1 0
F0-05
Auxiliary frequency
Y relative value
selection
0: Relative to maximum
frequency
1: Relative to main
frequency X
1 0
F0-06
Auxiliary frequency
Y range
0%–100% 1% 100%