Appendix IS300 Series Servo Drive User Manual
- 76 -
Function
Code
Name Setting Range Min. Unit Default Property
F0-07
Frequency source
selection
0:
Main frequency source X
1: X and Y operation
2: Switchover between X
and Y
3: Switchover between X
and "X and Y operation"
4: Switchover between Y
and "X and Y operation"
1 0 ☆
F0-08 Preset frequency
0.00-maximum frequency
(F0-10)
0.01 Hz 50.00 Hz ☆
F0-09 Rotating direction
0: Directions are the same.
1: Directions are reverse.
1 0 ☆
F0-10
Maximum
frequency
50.00–600.00 Hz 1 200.00 Hz ★
F0-11
Source of upper
limit of output
frequency
0: Set by F0-12
1: AI1
2: AI2
3: AI3
4: Reserved
5: Via communication
1 0 ★
F0-12
Upper limit of
output frequency
Frequency lower limit (F0-
14) to maximum frequency
(F0-10)
0.01 Hz 200.00 Hz ☆
F0-13 Upper limit offset
0.00Hz to maximum
frequency (F0-10)
0.01 Hz 0.00 Hz ☆
F0-14
Lower limit of
output frequency
0.00Hz to upper limit of
output frequency (F0-12)
0.01 Hz 0.00 Hz ☆
F0-15 Carrier frequency 0.5–16.0 kHz 0.1 kHz
Model
dependent
☆
F0-16
Carrier frequency
adjustment
selection
0: Fixed PWM, carrier
frequency temperature
adjustment invalid
1: Random PWM, carrier
frequency temperature
adjustment invalid
2: Fixed PWM, carrier
frequency temperature
adjustment valid
3: Random PWM, carrier
frequency temperature
adjustment valid
1 2 ☆
F0-17
Acceleration time 1
0.0–6500.0s 0.1s 20.0s ☆
F0-18
Deceleration time 1
0.0–6500.0s 0.1s 20.0s ☆
Group F1: Motor Parameters