EasyManua.ls Logo

Inovance IS 300 Series - Page 78

Inovance IS 300 Series
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IS300 Series Servo Drive User Manual Appendix
- 77 -
Function
Code
Name Setting Range Min. Unit Default Property
F1-00
Motor type
selection
0: Common asynchronous
motor
1: Variable frequency
asynchronous motor
2: PMSM
1 2
F1-01 Rated power 0.4–1000.0kW 0.1 kW
Model
dependent
F1-02 Rated voltage 0–440 V 1 V
Model
dependent
F1-03 Rated current 0.01–655.35 A 0.01 A
Model
dependent
F1-04 Rated frequency 0.00–max. frequency 0.01 Hz
Model
dependent
F1-05
Rated rotational
sped
0–30000 rpm 1 rpm
Model
dependent
F1-06 to
F1-10
Reserved - - -
F1-11 Shaft D inductance 0–65535 1
Model
dependent
F1-12 Shaft Q inductance 0–65535 1
Model
dependent
F1-13 Stator resistance 0–65535 1
Model
dependent
F1-14 Unit 00–12 01
Model
dependent
F1-15 Counter EMF 0–65535 V 1
Model
dependent
F1-16 Tuning selection
0: No operation
1: Static tuning (low speed)
2: Dynamic tuning (hi-
speed)
3: Tuning method 3
1 0
Group F2: Vector Control Parameters
F2-00
Speed loop
proportional gain1
0–100 1 60
F2-01
Speed loop
integration time 1
0.01–10.00s 0.01s 0.30s
F2-02
Switchover
frequency 1
0.00–F2-05 0.01 Hz 5.00 Hz
F2-03
Speed loop
proportional gain 2
0–100 1 60
F2-04
Speed loop
integration time 2
0.01–10.00s 0.01s 0.30s

Related product manuals