Appendix IS300 Series Servo Drive User Manual
- 84 -
Function
Code
Name Setting Range Min. Unit Default Property
F6-07
Acceleration/
Deceleration mode
0: Linear acceleration/
deceleration
1: S-curve acceleration/
deceleration
1 0
F6-08
Time proportion
of S-curve start
segment
0.0%–40.0% 0.1% 30.0%
F6-09
Time proportion
of S-curve end
segment
0.0%–40.0% 0.1% 30.0%
F6-10 Stop mode
0: Decelerate to stop
1: Coast to stop
1 0
F6-11
DC braking starting
frequency at stop
0.00 Hz–maximum
frequency
0.01 Hz 0.00 Hz
F6-12
DC braking waiting
time at stop
0.0–36.0s 0.1s 0.0s
F6-13
DC braking current
at stop
0%–100% 1% 0%
F6-14
DC braking time at
stop
0.0–36.0s 0.1s 0.0s
F6-15 Brake use ratio 0%–100% 1% 100%
Group F7: Operation Panel and Display Parameters
F7-00
LCD language
selection
0: Chinese
1: English
1 0
F7-01
MF.K Key function
selection
0: MF.K key invalid
1: Switchover between
operation panel and
remote command
channel (terminal or
communication)
2: Switchover between
forward rotation and
reverse rotation
3: Forward JOG
4: Reverse JOG
1 0
F7-02
STOP/RESET key
function
0: Valid only in operation
panel control
1: Stop function of the
STOP key valid in terminal
control
2: Reset function of the
STOP key valid in terminal
control
3: Both stop and reset
functions of the STOP key
valid in terminal control
1 2