Mechanical Installation (T1 to T9 Models)
‑86‑
3. Remove the two screws in position ①.
4. Snap the conduit box into the AC drive from top to bottom (as shown in Figure ①),
tighten the two screws in position ②, and tighten the two M4 x 8 self‑tapping screws
in position ③.
Note
● The screws in Figure ② are the screws that have been removed at ① in Step 3.
● The number of the screws to be fastened in Figure ③ varies with models. Two
screws are required for T5 models, and four screws are required for T6 models.
The screws are delivered with the conduit box and are to be fastened in the same
way.