Mechanical Installation (T10 to T12 Models)
90
Keep combustible and explosive materials away from the AC drive.
5.3 Heat Dissipation Design
Consider the space for heat dissipation for installation of T9 to T12 models in a
cabinet. A self‑ventilated cabinet has no fan on the top.
Figure 5‑1 Self‑ventilated cabinet
Table 5–1 Specifications of a self‑ventilated cabinet
AC Drive Model
Quantity of Fans
Total Airflow
(CFM)
Effective Area of
the Cabinet Air
Inlet (mm
2
)
Effective Area of
the Cabinet Air
Outlet (mm
2
)
T9 (132 kW)
2 541 31809 50894
T9 (160 kW)
2 620 31809 50894
T10 (200 kW)
2 586 31809 50894
T10 (220 kW)
2 722 31809 50894
T11 (250 kW)
3 789 47713 76341
T11 (280 kW)
3 882 47713 76341
T12 (315 kW)
3 644 47713 76341
T12 (355 kW)
3 796 47713 76341