Mechanical Installation (T10 to T12 Models)
‑99‑
Figure 5‑13 Removing the air filter baffle
5.5 Removing and Installing the Cover
5.5.1 Removing the Cover
When wiring the control circuit, remove the cover from the AC drive before
proceeding with any jumper operation or connecting any PG card or extension card.
When removing the cover, hold the cover with your hands and carefully lift the lower
part of the cover to prevent the cover from falling off. Failure to comply may result in
equipment damage or human injury.
PPrreerreeqquuiissiitteess
Before removing the cover, ensure that the AC drive has been powered off for longer
than 10 minutes.
PPrroocceedduurree
1. Use a screwdriver to unscrew the six fixing screws of the cover.
2. Hold the cover with your hands, and lift it in the arrow direction to remove it.