EtherNet/IP Communication
252
Set FD‑37 to 1 to enable the DHCP function, power on the AC drive again, and connect
the PC and AC drive to the same network.
Choose BootP-DHCP Tool from the start menu, and select the network adapter.
After power‑on, you can find the device request in the BootP DHCP EtherNet/IP
Commissioning Tool.
Right‑click the request and choose Add Relation.
Set the IP address and click OK.