Option Selection
‑127‑
Table 4–6 Selection of AC input reactors (three‑phase 380 V to 480 V) (Inovance)
Structure Model
Applicable Reactor
Inductance (mH) Loss (W)
T1
MD580‑4T2R1B MD‑ACL‑10‑5‑4T 5 50
MD580‑4T3R1B MD‑ACL‑10‑5‑4T 5 50
MD580‑4T3R8B MD‑ACL‑10‑5‑4T 5 50
MD580‑4T5R1B MD‑ACL‑10‑5‑4T 5 50
MD580‑4T7R2B MD‑ACL‑10‑5‑4T 5 50
MD580‑4T9B MD‑ACL‑10‑3‑4T 3 50
T2
MD580‑4T13B MD‑ACL‑15‑1.45‑4T 1.45 100
MD580‑4T17B MD‑ACL‑15‑1.45‑4T 1.45 100
T3
MD580‑4T25B MD‑ACL‑40‑1.45‑4T 1.45 100
MD580‑4T32B MD‑ACL‑40‑1.45‑4T 1.45 100
T4 MD580‑4T37B MD‑ACL‑50‑0.28‑4T 0.28 ‑
T5
MD580‑4T45(B)
MD‑ACL‑60‑0.24‑4T‑2% 0.24 ‑
MD580‑4T60(B)
MD‑ACL‑80‑0.17‑4T‑2% 0.17 ‑
T6
MD580‑4T75(B)
MD‑ACL‑80‑0.17‑4T‑2% 0.17 ‑
MD580‑4T91(B)
MD‑ACL‑90‑0.16‑4T‑2% 0.16 ‑
T7
MD580‑4T112(B)
MD‑ACL‑120‑0.12‑4T‑2% 0.12 ‑
MD580‑4T150(B)
MD‑ACL‑150‑0.095‑4T‑2% 0.095 ‑
T8
MD580‑4T176(B)
MD‑ACL‑200‑0.07‑4T‑2% 0.07 ‑
MD580‑4T210 MD‑ACL‑250‑0.07‑4T‑2% 0.07 ‑
MD580‑4T253 MD‑ACL‑250‑0.056‑4T‑2% 0.056 ‑
T9
MD580‑4T304 MD‑ACL‑330‑0.042‑4T‑2% 0.042 ‑
MD580‑4T377 MD‑ACL‑330‑0.028‑4T‑2% 0.028 ‑
T10
MD580‑4T426‑L MD‑ACL‑490‑0.028‑4T‑2% 0.028 ‑
MD580‑4T465‑L MD‑ACL‑660‑0.028‑4T‑2% 0.028 ‑
T11
MD580‑4T520‑L MD‑ACL‑660‑0.021‑4T‑2% 0.021 ‑
MD580‑4T585‑L MD‑ACL‑660‑0.021‑4T‑2% 0.021 ‑
T12
MD580‑4T650‑L MD‑ACL‑800‑0.021‑4T‑2% 0.021 ‑
MD580‑4T725‑L MD‑ACL‑800‑0.017‑4T‑2% 0.017 ‑
MD580‑4T820‑L MD‑ACL‑1000‑0.017‑4T‑2% 0.017 ‑