Product Information
‑22‑
Item
Technical Specifications
Environ
ment
Operating
location
Indoors without direct sunlight, dust, corrosive gas,
combustible gas, oil mist, water vapor, drip, or salt
Altitude 1000 m and below: no derating Above 1000 m: Derate 1%
for every additional 100 m. Above 3000 m: Contact
Inovance.
(Note: The maximum altitude for T1 models is 2000 m. For
altitude above 2000 m, contact Inovance.)
Ambient
temperature
–10°C to +50°C. For temperature between 40°C to 50°C,
derate 1.5% for every additional 1°C.
Humidity Less than 95% RH, non‑condensing
Vibration
Less than 5.9 m/s
2
(0.6 g)
Storage
temperature
–20ºC to +60ºC
1.4 Components
1.4.1 Overview
AC drives of the T1 to T12 models use the sheet metal structure.