Option Selection
‑165‑
Table 4–39 Installation dimensions of output reactors (60 A to 110 A) (unit: mm)
Series A B C D E F G
60 A and 72 A 155 Max. 125 Max. 190 130 70 8 x 12 16 mm
2
90 A 190 Max. 115 Max. 225 170 57 8 x 12 35 mm
2
110 A 190 Max. 130 Max. 220 170 67 8 x 12 35 mm
2
Figure 4‑44 Dimensions of output reactors (124 A to 330 A)
Table 4–40 Installation dimensions of output reactors (124 A to 1100 A) (unit: mm)
Series A B C D E F G
124 A 190 Max. 180 Max. 160 170 67 8 x 12 Ø8
143 A 190 Max. 180 Max. 160 170 77 8 x 12 Ø8
156 A and
170 A
190 Max. 180 Max. 160 170 77 8 x 12 Ø10
182 A 210 Max. 180 Max. 185 175 97 8 x 12 Ø10
230 A 240 220 190 119 11 x 15 Ø12
280 A 240 235 190 133 11 x 15 Ø12
330 A 240 240 190 135 11 x 15 Ø12
400 A and
500 A
240 220 190 119 11 x 15 Ø11
600 A and
680 A
240 230 190 128 11 x 15 Ø11
790 A 300 218 240 136 11 x 15 Ø11
910 A 300 228 240 148 11 x 15 Ø11
1100 A 360 250 310 144 11 x 15 Ø11