Product Information
‑18‑
Table 1–4 Electrical specifications (three‑phase 380 V to 480 V) (T7 to T9 models)
Item
Specifications
Model: MD580‑4Txxxxx
112(B)
150B 176B 210 253 304 377
Structure T7 T8 T9
Output
Power (kW) 55P/45G 75P/55G 90P/75G 110P/90G
132P/
110G
160P/
132G
200P/
160G
Rated output current
(A)
112P/91G
150P/
112G
176P/
150G
210P/
176G
253P/
210G
304P/
253G
377P/
304G
Output voltage Three‑phase 0 V to input voltage
Max. output
frequency
599 Hz (editable through parameter setting)
Carrier frequency
0.8 kHz to 12.0 kHz
(automatically
adjusted based on
load characteristics)
0.8 kHz to 6.0 kHz (automatically adjusted based on load
characteristics)
Overload capacity
P‑type AC drive: 110% rated current for 60s; G‑type AC drive: 150% rated current
for 60s
Input
Rated input current
(A)
111P/89G
143P/
106G
167P/
139G
198P/
164G
239P/
196G
295P/
240G
359P/
287G
Rated voltage/
frequency
Three‑phase 380 VAC to 480 VAC, 50/60 Hz
Voltage range Allowed fluctuation: –15% to +10%; actual allowed range: 323 VAC to 528 VAC
Frequency range Allowed fluctuation: ±5%; actual allowed range: 47.5 Hz to 63 Hz
Power capacity (kVA)
81 97 127 150 179 220 263
Heat
dissipation
Thermal design power
(kW)
1.01 1.21 1.57 1.81 2.14 2.85 3.56
Air flow (CFM)
122.2 122.2 218.6 287.2 354.2 547 627
Overvoltage class
OVC III
Pollution degree
PD2
IP rating IP20 (open type, for IEC products)
Table 1–5 Electrical specifications (three‑phase 380 V to 480 V) (T10 to T11 models)
Item
Specifications
Model: MD580‑4Txxxxx 426 465 520 585
Structure T10 T11
Output
Power (kW) 220P/200G 250P/220G 280P/250G 315P/280G
Rated output current
(A)
426P/377G 465P/426G 520P/465G 585P/520G
Output voltage Three‑phase 0 V to input voltage
Max. output frequency 599 Hz (editable through parameter setting)
Carrier frequency 0.8 kHz to 6.0 kHz (automatically adjusted based on load characteristics)
Overload capacity
P‑type AC drive: 110% rated current for 60s; G‑type AC drive: 150% rated current
for 60s