- 6 -
Introduction
Function Description Remarks
Idle elevator returning
to base oor
In automatic running state, the elevator automatically returns
to the set parking oor and waits for passengers if there is no
car call or hall call within the set time.
F9-00 (Idle time before
returning to base oor)
Landing at another
oor
If the door open time exceeds the door open protection time
but the door open limit signal is still inactive, the elevator
closes the door and then automatically runs to the next landing
oor; the system reports fault Err55.
-
Forced door close
When the door fails to close within the set time due to the
action of the light curtain or safety edge, the elevator enters
the forced door close state, closes the door slowly, and gives
a prompt tone.
-
Cancellation of wrong
calls
Passengers can press the button consecutively twice to cancel
wrong calls.
-
Service oor setting
You can enable or disable the system service for certain oors
exibly based on actual requirements.
F6-05, F6-06, F6-35
Time-based oor
service
You can exibly set the time periods and corresponding
service oors or select the service oors by using the service
oor switchover switch.
-
Independent running
The elevator does not respond to any call, and the door
needs to be closed manually. In the case of group control, the
elevator runs independently out of the group control system.
Signal input: CCB JP23
Attendant running
In attendant state, the running of the elevator is controlled by
the attendant.
Signal input: CCB JP21
Low-speed self-rescue
When the elevator is in non-inspection state and stops at non-
leveling area, the elevator automatically runs to the leveling
area at low speed if the safety requirements are met, and then
opens the door.
-
Door control function
You can set whether the system keeps outputting commands
after door open limit and door close limit based on the type of
the door machine.
-
Car arrival gong
After the elevator arrives at the destination oor, the CTB
gives a prompt tone.
-
Hall arrival forecast
indicator
When the elevator will arrive at the destination oor soon, the
hall arrival forecast indicator becomes ON.
HCB output
Hall arrival gong
After the elevator will arrive at the destination oor soon, the
system outputs the hall arrival gong.
HCB output
Hall I/O extension
function
If the hall I/O terminals are not sufcient, more terminals can
be provided by using an
MCTC-KZ-G1 board.
-
Car I/O extension
function
If the car I/O terminals are not sufcient, more terminals can
be provided by using an MCTC-KZ-G1 board.
-
Button stuck check
The system can automatically identify whether a hall call
button is stuck and cancel the stuck call, preventing the
condition that the elevator cannot close and run due to stuck
hall calls.
FE-32 Bit4
Automatic startup
torque compensation
The system automatically implements startup torque
compensation based on the current car load, achieving
smooth startup and improving the riding comfort.
F8-01 (Pre-torque
selection)
Direct travel ride
The system automatically calculates and generates the
running curves based on the distance, enabling the elevator to
directly stop at the leveling position without creeping.