Introduction
Function Description Remarks
Automatic generation
of optimum curve
The system automatically calculates the optimum speed curve
compliant with the human-machine function principle based on
the distance, without being limited by the number of curves or
short oor.
Service suspension
output
When the elevator cannot respond to hall calls, the
corresponding terminal outputs the service suspension signal.
-
Running times
recording
In automatic running state, the system automatically records
the running times of the elevator.
Recorded in F9-11 and
F9-12
Running time
recording
The system automatically records the accumulative power-on
time, working hours, and working days of the elevator.
Recorded in F9-09
Automatic door
open upon door lock
abnormality
If the system detects that the door lock circuit is abnormal
during door open/close, the elevator automatically opens and
closes the door again, and reports a fault after the set door
open/close times is reached.
VIP service
The elevator rst directly runs to the VIP oor and provides
services for special persons.
-
Disability service
When the elevator is waiting at the leveling position, if there
is a call at this oor from the disability operation box, the door
open holding time is prolonged. It is the same for the back
door.
Fb-15 (Special door
open holding time)
Full-load direct running
When the car is full-loaded in automatic running state, the
elevator does not respond to hall calls from the passing oors.
These halls calls, however, can still be registered, and will
be executed at next time of running (in the case of single
elevator) or by another elevator (in the case of parallel/group
control).
-
Overload protection
When the car load exceeds the elevator rated load, the
elevator alarms and stops running.
-
Fault data recording
The system automatically records detailed information of
faults, which helps improve the efciency of maintenance and
repair.
Groups FC, E0 to E9
Inspection-related Functions
Simple maintenance
keypad
The 3-button keypad on the MCB provides the functions such
as commissioning the running oors and door open/close.
-
Operation box
commissioning
The operation panel can be connected to the system in
the car for elevator commissioning, which improves the
commissioning efciency.
-
Shaft auto-tuning
Shaft auto-tuning is required before rst-time automatic
running. During shaft auto-tuning, the elevator runs from
the bottom oor to the top oor at the inspection speed and
automatically records all position signals in the shaft.
F1-11 (Auto-tuning
mode)
User-dened
parameter display
You can view the parameters that are modied and different
from the default setting.
FP-02
Inspection running
After entering the inspection state, the system cancels
automatic running and related operations. You can press
the up or down call button to make the elevator jog at the
inspection speed.
-
Motor auto-tuning
With simple parameter setting, the system can obtain the
motor parameters no matter whether the motor is with-load or
without load.
-

Other manuals for Inovance Monarch NICE-L-C-4037F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance Monarch NICE-L-C-4037F and is the answer not in the manual?

Inovance Monarch NICE-L-C-4037F Specifications

General IconGeneral
BrandInovance
ModelMonarch NICE-L-C-4037F
CategoryController
LanguageEnglish

Related product manuals