3.3. Restoring the MAX V CPLD to the Factory Setting
You can restore the original factory contents to the MAX V CPLD on the development
board. Make sure you have the Quartus Prime software installed, and then perform
these steps.
1. Set the board switches to the factory default settings described in the Factory
Default Switch and Jumper Settings section.
Attention: DIP switch SW4.4 includes the MAX V device in the JTAG chain.
2. Launch the Quartus Prime Programmer.
3. Click Auto Detect.
4.
Click Add File and select cycloneVSX_5csxfc6df31_soc\factory_recovery
\max<no_ver>.pof.
5. Turn on the Program/Configure option for the added file.
6. Click Start to download the selected configuration file to the MAX V CPLD.
Configuration is complete when the progress bar reaches 100%.
To ensure that you have the most up-to-date factory restore files and product
information, refer to the Cyclone V SoC Development Kit page of the Intel website.
Related Information
• Factory Default Switch and Jumper Settings on page 15
• Cyclone V SoC Development Kit Website
3.4. Restoring CFI Flash Device to the Factory Defaults
To program the factory image to the flash device in the Quartus Prime Programmer, do
the following steps:
1. On the Tools menu in the Quartus Prime software, click Programmer.
2. In the Programmer window, click Auto-Detect.
Note: If you do not see Intel FPGA Download Cable or the board's embedded Intel
FPGA Download Cable II listed next to Hardware Setup, refer to the
Quartus Prime Software and Driver Installation section.
3.
Click Add File and open cycloneVSX_5csxfc6df31_soc\factory_recovery
\max2_PFL_writer.pof.
4.
Turn on the Program/Configure option for the .pof file.
5. Click Start to download the selected configuration file to the MAX V CPLD.
Configuration is complete when the progress bar reaches 100%.
6. Click Auto Detect and a flash device should show up attached to the MAX V in the
main window.
7. Double-click the graphic of the flash device in the device chain pane to display the
Device's Properties dialog box.
8.
Select the flash image .pof file: cycloneVSX_5csxfc6df31_soc
\factory_recovery\output_file.pof.
9.
Once the flash image .pof is attached in the Quartus Prime Programmer, turn on
Page_1 and Option Bits. (Page_0 is reserved for the GSRD factory design.)
3. Development Kit Setup
830285 | 2024.10.07
Cyclone
®
V SoC Development Kit User Guide
Send Feedback
22