Intel® Server Board S2400SC TPS Jumper Blocks
Revision 2.0 Intel order number G36516-002
The server board has several 3-pin jumper blocks that can be used to configure, protect, or
recover specific features of the server boards.
The following symbol identifies Pin 1 on each jumper block on the silkscreen: ▼
Figure 23. Jumper Blocks (J1C4, J1C5, J1C6, J2J2, J2J3, J2J4)
Table 45. Server Board Jumpers (J1C4, J1C5, J1C6, J2J2, J2J3, J2J4))
Force Update
BMC Firmware Force Update Mode – Disabled (Default)
BMC Firmware Force Update Mode – Enabled
Recovery
Pins 1-2 should be jumpered for normal system operation. (Default)
The main system BIOS does not boot with pins 2-3 jumpered. The system only boots from
EFI-bootable recovery media with a recovery BIOS image present.
Default
These pins should have a jumper in place for normal system operation. (Default)
If pins 2-3 are jumpered with AC power plugged in, the CMOS settings clear in 5 seconds.