EasyManua.ls Logo

Intel S2400SC - Jumper Blocks; BIOS Default (CMOS Clear) and Password Clear Usage Procedure

Intel S2400SC
161 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Intel® Server Board S2400SC TPS Jumper Blocks
Revision 2.0 Intel order number G36516-002
97
9.
Jumper Blocks
The server board has several 3-pin jumper blocks that can be used to configure, protect, or
recover specific features of the server boards.
The following symbol identifies Pin 1 on each jumper block on the silkscreen:
Figure 23. Jumper Blocks (J1C4, J1C5, J1C6, J2J2, J2J3, J2J4)
Table 45. Server Board Jumpers (J1C4, J1C5, J1C6, J2J2, J2J3, J2J4))
Jumper Name
Pins
System Results
J1C4: BMC
Force Update
1-2
BMC Firmware Force Update Mode Disabled (Default)
2-3
BMC Firmware Force Update Mode Enabled
J1C5: BIOS
Recovery
1-2
Pins 1-2 should be jumpered for normal system operation. (Default)
2-3
The main system BIOS does not boot with pins 2-3 jumpered. The system only boots from
EFI-bootable recovery media with a recovery BIOS image present.
J2J3: BIOS
Default
1-2
These pins should have a jumper in place for normal system operation. (Default)
2-3
If pins 2-3 are jumpered with AC power plugged in, the CMOS settings clear in 5 seconds.

Table of Contents

Other manuals for Intel S2400SC

Related product manuals