Intel® Light Guided Diagnostics Intel® Server Board S2400SC TPS
Intel order number G36516-002 Revision 2.0
102
10.
Intel
®
Light Guided Diagnostics
The server board has several on-board diagnostic LEDs to assist in troubleshooting board-level
issues. This section provides a description of the location and function of each LED on the
server boards.
10.1
5 V Stand-by LED
Several server management features of these server boards require a 5 V stand-by voltage
supplied from the power supply. The features and components that require this voltage that
must be present when the system is “Off” include the Integrated BMC, on-board NICs, and
optional Intel
®
RMM4/RMM4 Lite connector with Intel
®
RMM4/RMM4 Lite installed.
The LED is located near the main power connector on the lower left corner of the server board
and is labeled “5VSB_LED. It is illuminated when AC power is applied to the platform and 5 V
stand-by voltage is supplied to the server board by the power supply.