Intel® Server Board S2400SC TPS Functional Architecture
Revision 2.0 Intel order number G36516-002 41
Software RAID with system providing memory and CPU utilization
Supported RAID Levels – 0,1,5,10
o 4 Port SATA RAID 5 available standard (no option key required)
o 8 Port SATA RAID 5 support provided with appropriate Intel
®
RAID C600
Upgrade Key
o No SAS RAID 5 support
Maximum drive support = 32 (in arrays with 8 port SAS), 16 (in arrays with 4 port SAS),
128 (JBOD)
Open Source Compliance = Yes (uses MDRAID)
OS Support = Windows 7*, Windows 2008*, Windows 2003*, RHEL* 6.2 and later,
SLES* 11 w/SP2 and later, VMWare* 5.x.
Utilities = Windows* GUI and CLI, Linux* CLI, DOS CLI, and EFI CLI
Uses Matrix Storage Manager for Windows*
MDRAID supported in Linux* (does not require a driver)
Note: No boot drive support to targets attached through SAS expander card
Integrated Baseboard Management Controller (BMC) Overview
The server board utilizes the I/O controller, Graphics Controller, and Baseboard Management
features of the Server Engines* Pilot-III Server Management Controller. The following is an
overview of the features as implemented on the server board from each embedded controller.
Figure 17. Integrated Baseboard Management Controller (BMC) Overview