Environmental Limits Specification Intel® Server Board S2400SC TPS
Intel order number G36516-002 Revision 2.0
building blocks to consult vendor datasheets and operating parameters to determine the amount
of airflow required for their specific application and environmental conditions. Intel Corporation
cannot be held responsible, if components fail or the server board does not operate correctly
when used outside any of their published operating or non-operating limits.
The following is the calculated Mean Time Between Failures (MTBF) 30 degree C (ambient air).
These values are derived using a historical failure rate and multiplied by factors for application,
electrical and/or thermal stress and for device maturity. You should view MTBF estimates as
“reference numbers” only.
Calculate standard: Telcordia* issue 2
Calculate Method: Method I-D
Temperature = 40 degree C
Environment = GB, GC – Ground Benign, Controlled
Model = Serial
Duty cycle = 100%
Component Quality: Level II
Adhere to De-rating data
Table 44. MTBF Estimate
Intel
®
Server Board
S2400SC
40 168,035
Server Board Power Distribution
This section provides power supply design guidelines for a system using the Intel
®
Server Board
S2400SC. The following diagram shows the power distribution implemented on this server
board. For power supply data, please refer to the chapter that describes the power system
options including 460W, 550W or 750W power supply. Please note the intent of
460W/550W/750W power supply data is to provide customers with a guide to assist in defining
and/or selecting a power supply for custom server platform designs that utilize the server boards
detailed in this document.