Intel® Server Board S2400SC TPS Intel® Light Guided Diagnostics
Revision 2.0 Intel order number G36516-002
BMC Boot/Reset Status LED Indicators
During the BMC boot or BMC reset process, the System Status LED and System ID LED are
used to indicate BMC boot process transitions and states. A BMC boot will occur when AC
power is first applied to the system. A BMC reset will occur after: a BMC FW update, upon
receiving a BMC cold reset command, and upon a BMC watchdog initiated reset. The following
table defines the LED states during the BMC Boot/Reset process.
Table 47. BMC Boot/Reset Status LED Indicators
BMC/Video memory test failed
Solid
Blue
Solid
Amber
Nonrecoverable condition. Contact your Intel
®
representative for information on replacing this
Both Universal Bootloader
-Boot) images bad
Solid
Blue
Solid
Amber
Nonrecoverable condition. Contact your Intel
®
representative for information on replacing this
-Boot
Blink
Blue
3Hz
Blink
Green
1Hz
Blinking green indicates degraded state (no manageability),
blinking blue indicates u-Boot is running but has not
transferred control to BMC Linux*. Server will be in this state
6-8 seconds after BMC reset while it pulls the Linux* image
*
Solid
Blue
Solid
Green
Solid green with solid blue after an AC cycle/BMC reset,
indicates that the control has been passed from u-Boot to
BMC Linux* itself. It will be in this state for ~10-~20
End of BMC boot/reset process.
Normal system operation
Off
Solid
Green
Indicates BMC Linux* has booted and manageability
functionality is up and running. Fault/Status LEDs operate