EasyManuals Logo

Intel S2400SC User Manual

Intel S2400SC
161 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #134 background imageLoading...
Page #134 background image
Appendix B: Integrated BMC Sensor Tables Intel® Server Board S2400SC TPS
Intel order number G36516-002 Revision 2.0
122
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System Status
Assert/De-
assert
Readable
Value/Off
sets
Event
Data
Rearm
Stand-
by
PCI Riser 1 Temperature
(PCI Riser 1 Temp)
27h
Platform-
specific
Temperatur
e
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
IO Riser Temperature
(IO Riser Temp)
28h
Platform-
specific
Temperatur
e
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
Hot-swap Backplane 1
Temperature
(HSBP 1 Temp)
29h
Chassis-
specific
Temperatur
e
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
Hot-swap Backplane 2
Temperature
(HSBP 2 Temp)
2Ah
Chassis-
specific
Temperatur
e
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
Hot-swap Backplane 3
Temperature
(HSBP 3 Temp)
2Bh
Chassis-
specific
Temperatur
e
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
PCI Riser 2 Temperature
(PCI Riser 2 Temp)
2Ch
Platform-
specific
Temperatur
e
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
SAS Module Temperature
(SAS Mod Temp)
2Dh
Platform-
specific
Temperatur
e
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
Exit Air Temperature
(Exit Air Temp)
2Eh
Chassis &
Platform
Specific
Temperatur
e
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
Network Interface Controller
Temperature
(LAN NIC Temp)
2Fh All
Temperatur
e
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
Fan Tachometer Sensors
(Chassis specific
sensor names)
30h
3Fh
Chassis &
Platform
Specific
Fan
04h
Threshold
01h
[l] [c,nc]
nc =
Degraded
c = Non-fatal2
As and
De
Analog R, T M -

Table of Contents

Other manuals for Intel S2400SC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S2400SC and is the answer not in the manual?

Intel S2400SC Specifications

General IconGeneral
BrandIntel
ModelS2400SC
CategoryMotherboard
LanguageEnglish

Related product manuals