EasyManua.ls Logo

Intel Xeon E5-2600 Series - Page 86

Intel Xeon E5-2600 Series
136 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Intel® Xeon® Processor E5-2600 Product Family Uncore Performance Monitoring
86 Reference Number: 327043-001
PROCHOT_EXTERNAL_CYCLES
• Title: External Prochot
• Category: PROCHOT Events
• Event Code: 0x0A
• Max. Inc/Cyc: 1, Register Restrictions: 0-3
• Definition: Counts the number of cycles that we are in external PROCHOT mode. This mode is
triggered when a sensor off the die determines that something off-die (like DRAM) is too hot and
must throttle to avoid damaging the chip.
PROCHOT_INTERNAL_CYCLES
• Title: Internal Prochot
• Category: PROCHOT Events
• Event Code: 0x09
• Max. Inc/Cyc: 1, Register Restrictions: 0-3
• Definition: Counts the number of cycles that we are in Interal PROCHOT mode. This mode is trig-
gered when a sensor on the die determines that we are too hot and must throttle to avoid damaging
the chip.
TOTAL_TRANSITION_CYCLES
• Title: Total Core C State Transition Cycles
• Category: CORE_C_STATE_TRANSITION Events
• Event Code: 0x0B
• Extra Select Bit: Y
• Max. Inc/Cyc: 1, Register Restrictions: 0-3
• Definition: Number of cycles spent performing core C state transitions across all cores.
VOLT_TRANS_CYCLES_CHANGE
• Title: Cycles Changing Voltage
• Category: VOLT_TRANS Events
• Event Code: 0x03
• Max. Inc/Cyc: 1, Register Restrictions: 0-3
• Definition: Counts the number of cycles when the system is changing voltage. There is no filtering
supported with this event. One can use it as a simple event, or use it conjunction with the occu-
pancy events to monitor the number of cores or threads that were impacted by the transition. This
event is calculated by or'ing together the increasing and decreasing events.
VOLT_TRANS_CYCLES_DECREASE
• Title: Cycles Decreasing Voltage
• Category: VOLT_TRANS Events
• Event Code: 0x02
• Max. Inc/Cyc: 1, Register Restrictions: 0-3
• Definition: Counts the number of cycles when the system is decreasing voltage. There is no filter-
ing supported with this event. One can use it as a simple event, or use it conjunction with the occu-
pancy events to monitor the number of cores or threads that were impacted by the transition.
VOLT_TRANS_CYCLES_INCREASE
• Title: Cycles Increasing Voltage
• Category: VOLT_TRANS Events
• Event Code: 0x01
• Max. Inc/Cyc: 1, Register Restrictions: 0-3

Table of Contents