5.2.1 Installation in a kitchen cabinet
The boiler can be placed between two kitchen cabinets or
inside one cabinet. Make sure, however, that there is suicient
ventilation below and above the boiler. If the boiler is placed
inside a cabinet, ventilation openings of at least 50cm
2
must
be created above as well as below.
The boiler must be installed on a wall that has suicient
strength to be able to bear the boiler filled with water.
There must be a Earthed fuse spur available at a maximum
distance of one (1) metre from the boiler. The condenstate
must be connected from the boiler and drain away to the
sewer.
To prevent freezing of the condensation drain piping, the boiler
must be installed in a frost-free area.
Make sure the boiler is easily accessible by ensuring that there
is suicient free space surrounding the boiler. This facilitates
the maintenance of the boiler, amongst other things.
5.2 Installation location
at least 50cm
2
at least 50cm
2
min. 200
H
min. 250
min. 50
277
450
min. 10