7.4 Clock function
Clock shown (P-on active)
T-on active
The boiler is equipped with a digital clock and oers the
possibility to program points in time for both CH operation and
DHW operation.
To activate the clock program the following parameters have to
be set:
For CH operation parameter P040 = 1
For DHW operation parameter P087 = 1
In CH operation 6 points can be programmed to switch from
CH o or CH on.
In DHW operation 4 points can be programmed to switch
the pre-heat function of the heat exchanger from on to
o. Also the pre-heat behavior of an external boiler can be
programmed in this mode.
Additionally the following special modes can be chosen:
In CH operation
P-on (Program on):
The boiler will respond only on CH demands within the
chosen time blocks. If the clock program does not contain
any valid switching points, the boiler will respond on any
CH demand. The actual time is shown on the le display
indicating that the clock program is active.
T-on (Temporary on):
The clock program will be temporary overruled. The
boiler will respond to every CH demand until the next "on"
switching point. On the le display t-ON will be shown.
On (Continuous on):
The boiler will respond to every CH demand without any time
limit.
O:
The boiler will not respond to any CH demand.
In DHW operation
P-on (Program on):
The appliance's DHW comfort function is switched on
continuously within the chosen time blocks . In this mode the
heat exchanger will be kept on temperature to assure instant
delivery of DHW. If the clock program does not contain any
valid switching points, the heat exchanger will continuously
be kept on temperature.
On (Continuous on):
The appliance's DHW comfort function is switched
on continuously. The heat exchanger will be kept on
temperature.
Eco:
The appliance's DHW comfort function is self learning
within the chosen time blocks. The appliance will adapt
to the pattern of use of the hot water tap. As a result, the
temperature of the heat exchanger will not be maintained
during the night or in case of long absence. If the clock
program does not contain any valid switching points, the self
learning feature is maintained.
O:
The temperature of the heat exchanger is not maintained, as
a result of which the delivery of hot domestic water takes a
little time. If there is no need for fast delivery of domestic hot
water, DHW comfort function can be switched o.