4.1.n.6.10 Engineer walk test 
 
If the Engineer walk test option is set to Yes, the zone is included in the Engineer 
walk test. See “1.2.5 Walk test” on page 50 for more details. 
4.1.n.6.11 User walk test 
 
If the User walk test option is set to Yes, the zone is included in the User walk 
test. See “1.2.5 Walk test” on page 50 for more details. 
4.1.n.6.12 Shock sensor 
 
The Shock sensor option activates the shock sensor functionality. If this option is 
set to Yes, the zone operates according to the settings configured in “4.1.n.7 
Gross and Pulse options” (see page 104). 
Only the first eight inputs on the control panel and first eight on the input 
expander support this option. 
4.1.n.6.13 Extend EE 
 
If the Extend EE option is Yes, the zone activation expands the entry time for the 
value defined by “5.n.5 Prealarm time” on page 115. 
Note: After entry timer times out, local alarm activates. 
4.1.n.6.14 Final door 
 
When the Final door option is set to Yes, the zone has the exit terminator 
functionality. If the zone is activated during the exit time, the exit timer is 
terminated after the Final Set delay has expired (see “8.1.3.5 Final set delay” on 
page 140) and the area is set. 
4.1.n.6.15 Key latch 
 
If the Key latch option is set to Yes, the key switch zone input is latching. If the 
zone state is active, the area is set. If the zone changes to normal, the area is 
unset.