74 Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
2.2.1.n.3.17 EE 2 buzzer
17 EE 2 buzzer
>Yes<
If the option is set to Yes, the buzzer of the selected keypad is active during
entry/exit time 2.
See ā€œ18. Entry/Exit 2ā€ on page 235 for more details.
2.2.1.n.3.18 1+3 keys
18 1+3 keys
>Yes<
If the option is set to Yes, the combination of 1 and 3 keys allows you to raise a
panic alarm.
See Advisor Advanced User Guide for more details.
This functionality is only available for ATS113x keypads.
2.2.1.n.4 Keypad menu
4>Keypad menu
>>>
The keypad menu provides access to the programming menu built-in to the
keypad. For more information, see the appropriate keypad manual.
2.2.1.n.5 Delete keypad
5 Delete keypad
>Cancel<
To remove the keypad, press Enter, select OK and press Enter again. The
keypad is deleted.
Note: Before removing a keypad, you should remove any outputs or condition
filters connected to the keypad.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix Advisor Advanced ATS 000A Series and is the answer not in the manual?

Interlogix Advisor Advanced ATS 000A Series Specifications

General IconGeneral
BrandInterlogix
ModelAdvisor Advanced ATS 000A Series
CategoryControl Panel
LanguageEnglish

Related product manuals