Page #144 background image
CHV180 series frequency inverter special for elevator Appendix D
.143.
Function
Code
Name Description
Factory
Setting
Mod
ify
LCD Display
P7.06
Running state
display
selection
1.Output speed
2.Reference speed
3.DC bus voltage
4.Output voltage
5.Output current
Other parameters
display is determined
by 16 bit binary digit
BIT0: Running
frequncy
BIT1: Rotation speed
BIT2: Output power
BIT3: Output torque
BIT4: Input terminal
state
BIT5: Output terminal
state
BIT6: AI1
BIT7: AI2
BIT8: Torque
compensation
BIT9: Pole position
BIT10~ BIT15:
Reserved
0x00FF
RUNNING
DISPLAY