INVT iMars MG series grid-tied solar inverters Monitoring communication
Enable the “Ethernet communication settings” in the pop-up dialog box, fill in the IP address and
port number. The port number needs to be the same as that of the “Network setting”.
(1)Communication verification of WiFi200 and terminal devices
Complete the "Communication setting" of WinExpert solar monitoring software according to the
above description. As shown in figure, if the "green light" on the below of the home page is on and
display “Online”, the communication between WiFi200 and monitoring devices is successful and it
can go to the next step.
Otherwise, as shown in figure, if the "red light" on the below of the home page is on and display
“Offline”, the communication between WiFi200 and monitoring devices is not successful, please
check WiFi200 network connections, network configuration and monitoring equipment again.
(2)Communication verification of WiFi200 and inverters
Ensure the successful communication between WiFi200 and monitoring devices, and then check
the communication. As shown in the figure, select “Search inverter” in the operation menu of
WinExpert software.
- 62 -