When connecting the BlueBox to the new embedded target for the first time, double
check that the debug adapter pinout matches with the target debug connector. Note
that a mismatch can result in a hardware failure.
When connecting the BlueBox to the new embedded target for the first time, double
check that the debug adapter pinout matches with the target debug connector. Note
that a mismatch can result in a hardware failure.
The debug adapter features resettable fuses on pins 9, 11, 12, 15, 17, 19 and 21. These protect
debug signals against overcurrent and cycle back to a conductive state after the excessive
current fades away. Signals on pins 6, 16, 18, 20 and 22-38 are protected via 47 ohm serial
resistors.
The debug adapter connects to the target via a 38-pin Mictor connector, for example Tyco
Electronics 5767055-1. A target should feature a matching part, for example Tyco Electronics
5767081-1 in SMT technology.