19
20-pin 1.27 x 2.54mm Compact TI-20 D. Adapter
Ordering code
IC50119
This debug adapter is used to connect the iC5000 and the iC5700 BlueBox to the Cortex-M
based target. It’s used to connect to the embedded target featuring a 20-pin 1.27 x 2.54 mm
target debug connector with the Compact TI-20 pinout.
The debug adapter connects to the 25cm 40-pin ribbon cable coming from the BlueBox and to
the target debug connector on the other side. Refer to the BlueBox User Manual for more
details on connecting the debug adapter.
The following pinout is valid on the target side:
Signal direction
Signal description
Signal
Pin
Pin
Signal
Signal description
Signal direction
O
Standard JTAG
TMS
1
2
nTRST
Standard JTAG
O
O
Standard JTAG
TDI
3
4
GND
Ground
I
Reference voltage
VTref
5
6
KEY
Not connected
I
Standard JTAG
TDO
7
8
GND
Ground
I
Return TCK
RTCK
9
10
GND
Ground
O
Standard JTAG
TCK
11
12
GND
Ground
I
Emulation pins
EMU0
13
14
EMU1
Emulation pins
I
I/O
System Reset
nSRST
15
16
GND
Ground
I
Emulation pins
EMU2
17
18
EMU3
Emulation pins
I
I
Emulation pins
EMU4
19
20
GND
Ground
20-pin Compact TI-20 pinout
When connecting the BlueBox to the new embedded target for the first time, double
check that the debug adapter pinout matches with the target debug connector. Note
that a mismatch can result in a hardware failure.

Other manuals for iSystem iC5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the iSystem iC5000 and is the answer not in the manual?

iSystem iC5000 Specifications

General IconGeneral
BrandiSystem
ModeliC5000
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals