43
When connecting the BlueBox to the new embedded target for the first time, double
check that the debug adapter pinout matches with the target debug connector. Note
that a mismatch can result in a hardware failure.
22-pin ERF8 DAP2 Debug Adapter features resettable fuses on pins 2, 4, 5, 6, 10, 11, 12, 17 and
22. These fuses protect debug signals against overcurrent and cycle back to a conductive state
after the excessive current fades away.
The debug adapter connects to the target via a 22-pin ERF8 connector, Samtec ASP-137971-02.
The target must have populated a matching part, for example Samtec ASP-137969-01, Samtec
Series ERF8, Rugged High Speed Socket.