When connecting the BlueBox to the new embedded target for the first time, double
check that the debug adapter pinout matches with the target debug connector. Note
that a mismatch can result in a hardware failure.
Mictor 38-pin Renesas RH850 Nexus 16-bit Debug Adapter features resettable fuses on pins 9,
11, 12, 15, 17, 19, 21, 37. Fuse on pin 33 is not assembled. The fuses protect debug signals
against overcurrent and cycle back to a conductive state after the excessive current fades
away. All other signals are protected via 47 ohm serial resistor.
The debug adapter connects to the target via a 38-pin Mictor connector, Tyco Electronics
5767055-1. A target should feature a matching part, for example Tyco Electronics 5767081-1 in
SMT technology.