System Commands
Copyright© Itech Electronic Co., Ltd. 10
Chapter2 System Commands
STATus:QUEStionable[:EVENt]?
This command can be used to read the value in query event register.The power
supply will return a decimal number corresponding to the binary weighted sum
of each unit digit of register. These digits will be latched. After executing this
command, the query event register will be cleared.
Arguments
None
Returns
<value>
Related Command
STATus:QUEStionable:ENABle
STATus:QUEStionable:ENABle
This command edits the enable register value of query event. In query, the power
supply will return a decimal number representing the binary weighted sum of the
enable register.
Description of the register.:
Bit 0
VO, Overvoltage
Bit 1/2
CO, Overcurrent
Bit 3
Retain 1
Bit 4
OP,Overpower
Bit 5
TO,Over-temperature
Bit 6
TtlO, Over-total power
Bit 7
MO, Memory error
Bit 8
Retain 2
Command syntax
STATus:QUEStionable:ENABle <value>
Arguments
<value> 065535
Example
STATus:QUEStionable:ENABle 16

Table of Contents

Other manuals for ITech IT7622

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT7622 and is the answer not in the manual?

ITech IT7622 Specifications

General IconGeneral
BrandITech
ModelIT7622
CategoryPower Supply
LanguageEnglish

Related product manuals