System Commands
Copyright© Itech Electronic Co., Ltd. 75
PARA,THREephase
Parameter 2PEAK Current control mode
IMME
TIME
Query syntax
PROTect:PEAK:CTR? <PARAllel|THREephase>
Returns
<IMME|TIME>
PROTect:PEAK:CTR?
This command is used to query the control mode of peak protection current.
Command syntax
PROTect:PEAK:CTR? <PARAllel|THREephase>
Arguments
Parameter 1Device working mode
PARA,HREephase
Returns
<IMME|TIME>
PROTect:RMS:TIME:MAX?
This command is used to query the maximum RMS time.
Command syntax
PROTect:RMS:TIME:MAX? <PARAllel|THREephase>
Arguments
Parameter 1Device working mode
PARA,HREephase ,
Returns
<float>
PROTect:RMS:TIME:MIN?
This command is used to query the minimum RMS time.