System Commands
Copyright© Itech Electronic Co., Ltd. 56
Command syntax
[SOURce:]LOOPspeed < A>,<LOW|HIGH>
Arguments
< A>
<LOW|HIGH>
Loop speed of phaseLow speed,High speed
Query syntax
[SOURce:]LOOPspeed? < A/B/C/ALL >
Returns
None
[SOURce:]LOOPspeed?
This command is used to query the loop speed of a phase.
Command syntax
[SOURce:]LOOPspeed? < A/B/C/ALL >
Arguments
< A/B/C/ALL >
Returns
<LOW|HIGH>
[SOURce:]DEVice:TYPE
This command is used to set the device type,single/paralle/threephase
Command syntax
[SOURce:]DEVice:TYPE <SINGle|PARAllel|THREephase>
Arguments
<SINGle|PARAllel|THREephase>
Query syntax
[SOURce:]DEVice:TYPE?
Returns
<SINGle|PARAllel|THREephase>
[SOURce:]NORMal:SYNC <DISable|ENABle>
This command is used to change the Balance or Unbalance mode in 3-Phase