System Commands
Copyright© Itech Electronic Co., Ltd. 17
mode(control from panel). In this mode ,all of keys on front panel is valid.
Command syntax
SYST:LOC
Arguments
None
Query syntax
None
SYSTem:RWLock
This command is transmit through interface, the same function as
SYST:REM,but the difference is: this command can lock “LOCAL” button
as well. When this command is executed, the “Local” button can’t switch
to local control mode.
Command syntax
SYSTem:RWLock
Arguments
None
Returns
None
SYSTem:DATE
This command is used to set the system date.
Command syntax
SYSTem:DATE < value >,< value >,< value >
Arguments
<value> yy
<value> mm
<value> dd
Example
SYSTem:DATE 2015,5,22
Query syntax
SYSTem:DATE?