Basic Operation
Category Parameter Initial Value
Resistance setting under
CVCR mode: Rs
Rated maximum resist-
ance value of the
instrument
Current setting under CRCC
mode: Is
0A
Resistance setting under
CRCC mode: Rs
Rated maximum resist-
ance value of the
instrument
Voltage setting under AUTO
mode: Vs
Rated voltage of the
instrument
Current setting under AUTO
mode: Is
0A
Power setting under AUTO
mode: Ps
0W
Resistance setting under AU-
TO mode: Rs
Rated maximum resist-
ance value of the
instrument
On/Off state Off
Config
menu
Operation mode CC
I-Rise Slope 0.1A/ms
I-Fall Slope 0.1A/ms
Von mode Latch
Von level 0V
On Delay/Off Delay 0s
• Last: Indicates when powered on, the instrument will remain the same
parameter settings and input status as last time you powered off the
instrument.
• Last+Off: Indicates when powered on, the instrument will remain the
same settings as last time you powered off the instrument, but the input
status is Off.
4. After the parameter settings are complete, press [Enter].