Function and Features
Copyright © ITECH Electronic Co., Ltd. 28
Memory
MEMORY
Work with Recall button to recall 100 sets
saved parameters
Group=(0-9)
0: represents 1-10 sets; 1: represents:
11-20 sets, by parity of reasoning.
Displ
DISPLAY ON TIMER
Screen displays loading time.
On
Start function.
Off(default)
Stop function.
Communication
COMMUNICATION
Select the interface for communication with
a computer.
RS232
Select the RS232 communication
interface.
4800, 8, N non parity check, 1, NONE
9600 O even parity check CTS/RTS
19200 E odd parity check XON/XOFF
38400
57600
115200
USBTMC
Select the USB communication interface.
GPIB
Select the GPIB communication interface,
Address(1-30)
LAN
Select the LAN communication interface.
Gateway= 192.168.0.1 Gate way setup.
IP= 192.168.0.125 IP Addr…
Mask= 255.255.255.0 Mask setup
Socket Port= 30000 Socket Port setup
CAN
Select the CAN communication interface.
This function is optional.
10K: Baud rate
Addr: Address of load
Prescaler: Prescaler
BS1 Value: Not settable
BS2 Value: Not settable
Protocol
PROTOCOL
Communication protocol selection
SCPI(Default)
SCPI protocol.
Extend-Table
Expand SCPI protocol for compatibility of
other machines.
Parallel
PARALLEL SETUP
Parallel mode set up
Single
Single mode
Slave
Act as a slave mode
Master
Act as a master mode
Total = 3
Set total number of instruments in parallel.
Restored to Factory Setting (>Reset)
This option is used to restore all settings in the system menu to factory setting
values. Select “YESand Press [Enter] to restore to factory setting values. In
this case, all set values in the system will be restored to factory setting values,
i.e., the (Def) mark values.
Power on (>Power-on)
This parameter determines the state of electronic load after power up. If you
select “Rst”, the default input parameter settings will be active after power up.
The default setup is 0V and 0A. If you select “Sav0”, then the electronic load will