Function and Features
Copyright © ITECH Electronic Co., Ltd. 51
mode as follows: voltage: 3V, maximum current value: 5A, and minimum
current value: 0A. After parameter setting in each step, press [ESC] to exit
setting menu. Press [Shift] + 4(Save) key for saving. Settings at each
step should be independently saved. Refer to the Correspondence
Table for saving position.
18. It is necessary to recall test files for running after editing auto test files.
Recall test file for running
To recall edited test files from EEPROM quickly after re-energizing instrument,
refer to the method below.
1. Press [Shift] + 6(Prog) keys.
PROGRAM
Run Recall Edit
2. Operate key, select Recall and press [Enter] key.
RECALL PROGRAM
Recall Program File=1
3. Operate key, select Run and press [Enter] key.
PROGRAM
Run Recall Edit
4. Display auto test file 1.
PRG01 STOP
5. Press [Shift] + . (Trigger) key.
Operate auto test file 1. Press [Shift] + 0 (Pause) key to pause auto test.
Press key for next step.
3.21 Parallel Function
This series of electronic load supports mutual parallel operation of same models
and to increase input power and input current. The figure below shows 3 pcs
electronic load in parallel, in which, the system bus is used for master-slave
connection
.