Function and Features
Copyright © ITECH Electronic Co., Ltd. 45
Operation steps
1. Press [Shift] + 3(List) keys.
LIST
On Recall Edit
2. Operate key and move to Edit. Press [Enter] key.
EDIT LIST
High-Rate Low-Rate
3. Operate key and move to the High-Rate and press [Enter] key.
EDIT LIST
Current Range=3A
4. Edit number of steps. Press 2 key to edit two steps. Press [Enter] key.
EDIT LIST
File Step=2(2-84)
5. Edit current value in step 1 and press [Enter] key.
EDIT LIST
Step 001 Level=1A
6. Edit slope in step 1 and press [Enter] key.
EDIT LIST
Step 001 Rate=0.1A/uS
7. Edit time in step 1 and press [Enter] key.
EDIT LIST
Step 001 Width=5S
8. Edit current value in step 2 and press [Enter] key.
EDIT LIST
Step 002 Level=2A
9. Edit slope in step 2 and press [Enter] key.
EDIT LIST
Step 002 Rate=0.1A/uS
10. Edit time in step 2 and press [Enter] key.
EDIT LIST
Step 002 Width=5S
11. Edit repeat count and press [Enter] key.
EDIT LIST
Repeat Count=3
12. Save all edited files and press [Enter] key.
EDIT LIST
Save List File=1(1-7)
13. Operate key and move to on. Press [Enter] key (The Trig lamp
that indicates VFD screen status is on). Press [Esc] key to exit setting.
LIST
On Recall Edit
14. Press [On/Off] key to open input and press [Shift] + .(Trigger) key
(Triggering key).