Technical Specifications
Copyright © ITECH Electronic Co., Ltd. 80
Model IT89135-150-2500
Rated value
(0
40
)
0.225V/250A 2.25V/2500A
Constant
voltage
mode
Range 0.1~18V 0.1~150V
Resolution 1mV 10mV
Accuracy ±(0.05%+0.05%FS) ±(0.05%+0.05%FS)
Constant
current
mode
Range 0~250A 0~2500A
Resolution 10mA 100mA
Accuracy ±(0.1%+0.1%FS) ±(0.2%+0.2%FS)
Constant
resistance
mode *1
Constant power
Mode *3
Range 135KW
Resolution 10W
Measuring range
Read-back
voltage
Range 0~18V 0~150V
Resolution 1mV 10mV
Accuracy ±(0.025%+0.025%FS) ±(0.025%+0.025%FS)
Read-back
current
Range 0~250A 0~2500A
Resolution 10mA 100mA
Accuracy ±(0.1%+0.1%FS) ±(0.2%+0.2%FS)
Read-back
power *2
Range 135KW
Resolution 10W
Accuracy ±(0.2%+0.3%FS)
Protection range
≒136KW
≒275A ≒2750A
≒157V
Overtemperatur
e protection
≒85℃
Short circuit
Current (CC)
≒275A ≒2750A
Voltage (CV) 0V 0V
Resistance (CR)
≒0.9mΩ ≒0.9mΩ
≒300KΩ
37U*3
*1.The voltage/current input is no less than 10%FS (FS indicates the full
scope).
*2.The scope of read-back resistance is
(1/(1/R+(1/R)*0.01%+0.08),1/(1/R-(1/R)*0.01%-0.08)).
*3.The voltage/current input is no less than 10%FS.