58
32
**
No The vacuum is not released The vaccum cannot be released. The vacuum valve might be stuck or dirty.
Contact a Service Technician.
33 Yes Necessary vacuum (xxxmbar) is
not reached within 1 min.
The vacuum cannot be built-up. Check the seal of the firing chamber,
vacuum hose, vacuum pump, pump fuse.
106 Yes Timer active - device is in standby The program cannot be started, because the unit was put into stand-by
mode by the timer (heating turned off). Deactivate the timer or extend the
time frame to be able to execute programs.
109 Yes Wrong Value HV or V2 Enter plausible values for HV or V2.
110 Yes HV > H (H2) Enter a lower value for HV or a higher value for H (Hx).
111 Yes Max. number firing protocols
reached.
The maximum number of protocol entries has been reached. Further
protocols will delete/overwrite existing entries.
150 Yes Memory Error Internal memory error. Please restart the furnace.
702 Yes Brief power failure during a
program in progress
A program in progress was interrupted by a short power outage. The
program is being continued.
801 Yes Vacuum drop An unacceptable vacuum drop has occurred.
802 Yes "The vacuum does not increase
(self-test)
A vacuum increase could not be measured! Check the following points: Is
the firing chamber tight (no contamination on the sealing surfaces)? Is the
vacuum hose connected? Is the vacuum pump connected? Is the fuse F1 in
order?
1302
**
Yes ATK2-calibration: preheat 962°C Error during calibration. Sample might be incorrectly inserted. Try again
with a new sample and make sure the sample shows the correct contact.
1501 Yes Hint -> heating muffel The heating muffle has **** working hours. Please perform a heater test
(diagnosis) and follow the instructions on the display and in the Operating
Instructions.
1510 Yes Temperature > VT at the start of a
firing program
The temperature in the firing chamber is higher than the predrying
temperature. To continue the programm nevertheless, press the Start
button.
1522 Yes SW-update: Error during update An error has occurred during the software update. Do NOT switch off the
furnace and try again. If the error reoccurs, try conducting the update via
PrograBaseX10.
1541 Yes Error during copying a file An error occurred while copying the file. Possible causes: File too large,
invalid file type
1815 Yes USB Stick There is no USB stick available or the stick is not prepared as an external
program memory. The USB stick can be prepared in the settings menu.
1835 Yes Media playback Playback of the file is not possible.
1900 Yes Data backup – recover The new software contains setting options which were not yet available at
the time of the data backup. Only the existing settings of the data backup
were restored.
1901 Yes Data backup – recover The new software contains program parameters which were not yet
available at the time of the data backup. Only the existing program
parameters of the data backup were restored.
1902 Yes Data backup – recover The new software includes program groups which were not yet available at
the time of the data backup. Only the existing program groups of the data
backup were restored.
1911 Yes Data backup – recover The new software includes program parameters which were not yet
available at the time of the data backup. Please check the individual
programs. The individual programs are no longer valid.
1912 Yes Data backup – recover The new software includes program groups which were not yet available at
the time of the data backup. Please check the individual program groups.
The individual program groups are no longer valid.
1920 Yes Data backup – recover The data backup could not be performed. Please install a newer software
version.
2010 Yes DSA The tooth region was not determined.
2020 Yes DSA The 3 shade guide teeth were not found.
2030 Yes DSA The contour of the tooth was not determined.
2041 Yes DSA The analysis region and the references differ significantly.
2042 Yes DSA The analysis area is invalid. Select an analysis area on a tooth surface.
2100 Yes DSA Unexpected error (# ****)