5. Safety Notes
Always keep the air vents on the sides and at the rear of the furnace free from obstruction.
Do not touch any parts that become hot during operation of the furnace. Burn hazard!
When removing hot components from the firing chamber (e.g. firing table, firing tray), make sure to place them on a
fire-proof surface.
Clean the furnace only with a dry, soft cloth. Do not use any solvents! Disconnect power before cleaning and allow the
furnace to cool down!
The furnace must be cool before it is packed for transportation.
Use original packaging for transportation purposes.
Remove the object plate from the firing chamber when transporting or shipping the device.
Before maintenance, repair or change of parts, the power must be disconnected and the furnace must be cool if it
needs to be opened.
If maintenance or repair has to be carried out with the power connected and the furnace open, only
qualified personnel who are familiar with the risks and dangers may perform the procedures (certified Service Centre).
After maintenance, the required safety tests (high voltage resistance, protective conductor, etc.) must be carried out.
Make sure that only fuses of the indicated type and rated current are used.
Use only original spare parts.
If it is assumed that safe operation is no longer possible, the power must be disconnected to avoid accidental operation.
If the furnace is visibly damaged, the power must be disconnected to avoid accidental operation.
Check the correct function of the device after storage under unfavourable conditions over an extended period of time.
If the furnace does not work properly, the power must be disconnected to avoid accidental operation.
The temperature range for faultless operation is +5°C to + 40°C (41°F to 104°F).
If the furnace has been stored at very low temperatures or high atmospheric humidity, it must be left to dry or to adjust
to room temperature for approx. 4 hours before it is operated (do not connect the power yet).
The furnace is tested for use at altitudes of up to 2000 m above sea level.
The furnace may only be used indoors.
Before leaving the factory, the furnace functions were tested for several hours. It is therefore possible that these tests
have caused slight discolouration of the insulation. Nevertheless, your Programat CS6 is still a brand new furnace.
Any disruption of the protective conductor either inside or outside the furnace or any loosening of the protective
conductor may lead to danger for the user in case of malfunction. Deliberate interruptions are not tolerated.
Materials developing harmful gases must not be fired!
The insulation contains polycrystalline wools and may release fibre dust. Do not raise dust with compressed air.
Use a vacuum cleaner with HEPA filter to remove it. The heating elements may only be dismounted by a qualified
After Sales Service Centre. Information regarding the Safety Data Sheet is also available from your After Sales
Service Centre.
In the case of serious incidents related to the product, please contact Ivoclar Vivadent AG, Bendererstrasse 2,
9494 Schaan/Liechtenstein, website: www.ivoclarvivadent.com, and your responsible competent authority.
The current Operating Instructions are available in the download section of the Ivoclar Vivadent AG website
(www.ivoclarvivadent.com).
Disposal information
The product must be disposed of according to the corresponding national legal requirements.

Other manuals for Ivoclar Vivadent Programat CS6

Related product manuals