ELECTRICAL REQUIREMENTS
SPECIFICATIONS
NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical
xed-trip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection
than what is displayed here. Always verify with your electrical service contractor that your circuit protection is
adequate and meets all applicable national and local codes. These numbers are provided in this manual simply for
reference and may change without notice at any given time.
VOLTS PHASE HZ
RINSE HEATER
RATINGS
TOTAL
AMPS
TYPICAL
ELECTRICAL CIRCUIT
208 1 50 12KW@240V 71 A 90 AMP
208 1 50 14KW@240V 78 A 100 AMP
230 1 50 12KW@240V 78 A 100 AMP
230 1 50 14KW@240V 86 A 110 AMP
TEMPSTAR Electrical Characteristics:
208 3 50 12KW@240V 45 A 60 AMP
208 3 50 14KW@240V 49 A 70 AMP
230 3 50 12KW@240V 48 A 60 AMP
230 3 50 14KW@240V 53 A 70 AMP
380 3 50 12KW@380V 29A 40 AMP
380* 3 50 14KW@208V 34A 45 AMP
415 3 50 12KW@415V 26 A 35 AMP
415 3 50 14KW@415V 29 A 40 AMP
440 3 50 12KW@460V 21 A 30 AMP
440 3 50 14KW@460V 25 A 35 AMP
208 1 60 12KW@240V 69 A 90 AMP
208 1 60 14KW@240V 76 A 100 AMP
230 1 60 12KW@240V 76 A 100AMP
230 1 60 14KW@240V 84 A 110 AMP
208 3 60 12KW@240V 43 A 60 AMP
208 3 60 14KW@240V 47 A 60 AMP
230 3 60 12KW@240V 46 A 60 AMP
230 3 60 14KW@240V 51 A 70 AMP
460 3 60 12KW@480V 22 A 30 AMP
460 3 60 14KW@480V 25 A 35 AMP
6
* This model is wired in a wye con guration for the heaters.