Operation
Panel
Indicati
on
Name
Possible fault
reason
Cor
rective action
LUO
Under voltage
during stop
1: Power supply
voltage abnormal
2: Phase missing
1: Check the power
supply voltage
2: Check power supply
and switch whether
there is phase missing
LU1
Under voltage
during
acceleration
1: Power supply
voltage
abnormal
2: Phase missing
3: There is large load
power start up in the
input
2: Check whether
peripheral setting
bad connection leads
phase missing
3: Please use
independent power
supply
LU2
Under voltage
during
deceleration
LU3
Under voltage
during
onstant speed
FbO
Fuse broken
1: The inverter fault
Please contact your
sales representative.
Fb1
Fb2
Fb3
OLO during
stop
Inverter
overload
1: Overload
2: Acceleration time
is too short
3: Torque boost is too
fast
4: V/F curve
incorrectly s
et
5: Under voltage of
input
6: Before motor
stops, inverter
starts up
7: Fluctuation or
blocking in loading
1; Reduce the load
weight or replace
larger capacity
inverter.
2: Increase
acceleration time
3: Reduce torque boost
rate
4: Set V/F curve over
agai
n
5: Check input
voltage, increase
inverter capacity
6: Adopt tracing
startup mode
7: Check load
OL1
during
accelerati
on
OL2
during
decelerati
on
OL3
during
constant
speed
c
8
104
Chapter 8 Troubleshooting and Fault Informatin
FC100 Series User Manaul

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Janson Controls FC100 Series and is the answer not in the manual?

Janson Controls FC100 Series Specifications

General IconGeneral
BrandJanson Controls
ModelFC100 Series
CategoryController
LanguageEnglish

Related product manuals