39
E6 Calibration weight not attached to fl ange
Code C28 812560, 812561, 812565, 812566.
Complaint During the calibration C115 or C83, at the end of one of the step 3 or 4 is displayed E6
Root cause
Calibration weight not attached to the ! ange
Transducer loosened
Service Code C75 (AdE1 and AdE2), C115, C84, C88
Actions to do
Perform the calibration C115 with the weight on the ! ange.
Re-adjust the transducer and calibrate with C115, C84, C88;
E8 Valve position was not entered
Code C28
Complaint During the Optimization / Minimization E8 comes up
Root cause The Optimization / Minimization operation has been performed unless enter the valve position
Service Code
Actions to do Repeat the Optimization / Minimization operation
E9 Optimisation was carried out incorrectly
Code C28
Complaint During the Optimization / Minimization E9 comes up
Root cause The Optimization / Minimization operation has been carried out incorrectly.
Service Code
Actions to do Repeat the Optimization / Minimization operation
E16 Calibration weight attached erroneously to fl ange
Code C28 812570, 812571
Complaint During the calibration C115 the balancer shows E16.
Root cause Calibration weight attached erroneously to ! ange
Service Code C115, C84, C88
Actions to do Repeat the calibration C115, C84, C88
E17 Wheel slipped on adapter
Code C28 492207
Complaint After the wheel spin the wheel stops and the balancer shows E17
Root cause Wheel slipped on the ! ange.
Service Code C74
Actions to do
Check wing nut
Check the shaft