49
0X001036 LINE ABOVE LIMIT
Check the main power supply with C55.
If the problem still persists:
Check the Power supply to wall plug
If the problem still persists:
Check the main power supply cord and plug.
If the problem still persists:
Check the main switch.
If the problem still persists:
Check power supply cable and connectors inside of the machine.
If the problem still persists:
Call Snap On
C Codes C55
0X001037 LINE BELOW LIMIT
Check the main power supply with C55.
If the problem still persists:
Check the Power supply to wall plug
If the problem still persists:
Check the main power supply cord and plug.
If the problem still persists:
Check the main switch.
If the problem still persists:
Check power supply cable and connectors inside of the machine.
If the problem still persists:
Call Snap On
C Codes C55
0X001038 MAIN SHAFT OPTOENCODER LED CURRENT ABOVE20 mA, TOO HIGH
Check the main shaft Optoencoder cable.
If the problem still persists:
Clean the main shaft Optoencoder band.
If the problem still persists:
Check the main shaft Optoencoder.
If the problem still persists:
Call Snap On.
C Codes C74, C75, C85
0X001039 MAINSHAFT OPTOENCODER LED CURRENT LESS 16 mA, TOO LOW
Check the main shaft Optoencoder ! at cable.
If the problem still persists:
Clean the main shaft Optoencoder band.
If the problem still persists:
Check the main shaft Optoencoder.
If the problem still persists:
Call Snap On
C Codes C74, C75, C85