C1 Resolution of unbalance readings
Options:
0 : Low resolution
1 : High resolution
Special function: None
Description:
WHEEL TYPE
Resolution of unbalance readings Suppression of minor
readings
Low High
1, 2, 3, 6 (car) 5 grams 1 grams threshold value x 1
4, 5 (light truck) 10 grams 2 grams threshold value x 2
1, 2, 3, 6 (car) 0.25 ounces 0.05 ounces threshold value x 1
4, 5 (light truck) 0.5 ounces 0.1 ounces threshold value x 2
The selected mode of operation can be transferred to the permanent memory.
Comments: The asterisk “*“ marks the factory-adjusted default.
C2 Suppression of minor unbalance readings
Options:
0 : Suppression o!
1 * : Suppression on
Special function: None
Description: In order to signal to the operator that the required balance quality for a correction plane has been
reached, the unbalance below the threshold set using C8 will be read out as zero. In some cases this suppression
may not be useful and can, therefore, be switched o! temporarily using the precision/FINE key, or permanently using
code C2.
The chosen mode of operation can be transferred to the permanent memory.
Comments: The asterisk “*“ marks the factory-adjusted default.
C3 Measurement units of unbalance readings
Options:
0 : Readings in gram
1 : Readings in ounce
Special function:None
Description: The state de" nes the measurement unit of the unbalance readings (gram/ounce) active after power-
on and execution of C0.
The chosen mode of operation can be transferred to the permanent memory.
Comments: None
C4 Compensation of adaptor unbalance
Options: None
Special function: None